is a 15 kW (20 HP) variable speed drive from the Easy Altivar 610 series, optimized for water, wastewater, and oil and gas applications. It provides high-efficiency control for three-phase asynchronous motors in fan and pump systems.
Key Specifications
Power Rating: 15 kW (20 HP) for Normal Duty; 11 kW (15 HP) for Heavy Duty.
Continuous Output Current: 31.7 A at 4 kHz (Normal Duty); 23.5 A at 4 kHz (Heavy Duty).
Supply Voltage: 380V to 460V AC, three-phase.
Protection Rating: IP20.
Overload Capacity: 120% for 60 seconds (Normal Duty) and 150% for 60 seconds (Heavy Duty).
Dimensions & Weight
This model uses a larger frame size than the 7.5 kW units.
Width: 171 mm (6.73 in)
Height: 360 mm (14.17 in)
Depth: 233 mm (9.17 in)
Net Weight: 7.2 kg to 7.73 kg (15.9 lb to 17.0 lb)
The Schneider Electric ATV610D15N4 (15 kW / 20 HP) is designed to act as the "brain" for high-power pump and fan systems. It focuses on reducing energy consumption and providing automated process control without the need for an external PLC.
Dedicated Process Functions
Multi-Pump Control: Manages up to 3 pumps in a lead/lag system. It automatically starts/stops auxiliary pumps based on demand to maintain constant pressure.
Sleep/Wake Function: Automatically puts the motor into "sleep" mode when demand is low (e.g., a closed valve) and "wakes" it when pressure drops, saving significant electricity.
Anti-Condensation Heating: Sends a low current to the motor when stopped to keep the windings warm and prevent moisture buildup in humid environments.
Check Valve Protection: Features a controlled ramp-down to prevent "water hammer" effects that can damage pipes and valves.
Integrated Control & Monitoring
PID Controller: Built-in logic for pressure or flow regulation. You can connect a pressure sensor directly to the drive to maintain a set point automatically.
Skip Frequency: Allows you to program up to 3 specific frequency bands to avoid, preventing the motor from running at speeds that cause mechanical resonance/vibration.
Underload/Overload Detection: Detects pump "dry run" conditions (underload) or pipe blockages (overload) and can trigger an alarm or stop the motor to prevent damage.
Technical I/O Capability
6 Discrete Inputs: 24V DC (Source/Sink).
3 Analogue Inputs: Configurable for 0-10V, 4-20mA, or PT100/PT1000 temperature sensors.
2 Analogue Outputs: For remote monitoring of speed, current, or torque.
3 Relay Outputs: Configurable for "Drive Running," "Fault," or "Speed Reached" signals.
Advanced Safety & Durability
3C3 & 3S3 Coating: The internal circuit boards are specially coated to survive in harsh chemical environments (common in wastewater and oil & gas).
Mains Protection: Protects against phase loss, line surges, and short circuits.
Tell us about your requirement
Price:
Quantity
Select Unit
50
100
200
250
500
1000+
Additional detail
Mobile number
Email
Name
Comapny Name
Phone Number
Email Id
City / State
Confirm Your Requirement
Verification Code
Did not receive yet?
Resend OTP
You’re Done!
We have received your requirements and will reply shortly with the best price.