About MD5202T5.5BS-INT AC Drive, Three Phase, 200V to 240V,5.5kw - Inovance Ac Drive
The Inovance MD520 5.5 kW Low-Voltage Drive (Model:
MD5202T5.5BS-INT) is a high-performance variable frequency drive (VFD) optimized for three-phase lower-voltage power grids. Unlike the previously requested 400V class models, the
2T designation specifies a 200 V to 240 V AC three-phase input rating, while the
B denotes an integrated, built-in braking chopper unit. [
1,
2,
3]
This 5.5 kW (7.5 HP) capacity model is constructed within the compact
T4 frame size enclosure footprint. [
1,
2,
3]
Physical Dimensions & Weight (T4 Frame Size)
- Height (Total Length): 11.02 inches (\(280\text{ mm}\))
- Width: 7.09 inches (\(180\text{ mm}\))
- Depth (Thickness): 6.65 inches (\(169\text{ mm}\))
- Net Weight: 9.48 lbs (\(4.3\text{ kg}\))
Panel Mounting Layout
If you are planning internal backplate mapping or pre-drilling cabinet subpanels, utilize these exact centerline parameters:
- Horizontal Pitch Spacing: 6.54 inches (\(166\text{ mm}\))
- Vertical Pitch Spacing: 10.47 inches (\(266\text{ mm}\))
- Mounting Screw Diameter: 0.24 inches (Designed for standard M5 fixing bolts)
Electrical & Operational Specifications
| Specification Metric [1, 2, 3, 5, 7] |
Engineering Data Value |
| Manufacturer |
Inovance Technology |
| Line Input Supply |
Three Phase, 200 V AC to 240 V AC (-15% to +10%) |
| Heavy Duty Power (HD) |
5.5 kW (7.5 HP) |
| Rated Output Current |
Approx. 25 A (at 200V class scaling) |
| Overload Capacity Profile |
Heavy Duty: 150% for 60s / Normal Duty: 110% for 60s |
| Output Frequency Spectrum |
0 Hz to 599 Hz |
| Braking Unit Hardware |
Built-in internal chopper circuit (requires external resistor only) |
| Safety Integration |
Standard dual-channel Safe Torque Off (STO) certified to SIL3 PL e |
| Enclosure Protection |
IP20 |
System Integration & Environment
- Unified Control Algorithms: Supports high-accuracy open-loop V/F, Sensorless Vector Control (SVC), and closed-loop Flight Vector Control (FVC) via expansion option modules. [1, 2, 3]
- Atmospheric Resilience: Built with standard 3C3 and 3S2 level conformal board coatings to insulate circuitry against conductive factory dust, moisture, and chemical vapor degradation. [1, 2]
- Industrial Communication: Standard Modbus-RTU terminals onboard with plug-in network support for PROFINET, EtherCAT, and CANopen. [, 2, 3]
Please inform me if you would like the minimum braking resistor resistance values (\(\Omega \)) recommended for this 200V drive, or if you need the required top and bottom clearance dimensions for layout cooling.